18
YASKAWA ELECTRIC
SIEP C730600 24A V1000 Option CANopen Technical Manual
8 Object Description
8
Object Description
◆
Communication Objects (DS 301)
■
Device Type
This object describes the type of the device and its functionality. It is composed of a 16 bit field which describes the device profile that is used and a
second 16 bit field which gives additional information about optional functionality.
■
Error Register
This register shows the fault status of the device. If any errors occurs in the device bit 0 (generic error) is set to one.
■
Pre-defined Error Field
This register provides a history of errors that occurred in the drive and have been signalized via the Emergency object. Subindex 0 contains the
number of errors. Subindexes 1 to FF contains a rolling list of error codes where subindex 1 always contains the last occurred error.
for a list of possible error codes.
Writing a 0 into subindex 0 resets the error field.
■
COB-ID SYNC Message
This object defines the COB-ID of the synchronization object (SYNC). Further it defines whether the device consumes or generates the SYNC.
■
Manufacturer Device Name
This object contains the Manufacturer device name.
■
Manufacturer Hardware Version
This object contains the Manufacturer hardware version.
■
Manufacturer Software Version
This object contains the Manufacturer software version It indicates the version number of the EEPROM.
■
Guard Time
This object contains the guard time.
■
Life Time Factor
This object contains the life time factor. It defines how often the guard time cannot be kept until an error is created.
■
Node Guarding Identifier
This object contains the node guarding identifier. It defines the identifier for the node guarding.
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
1000
–
Device Type
Read Only
No
Unsigned 32
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
1001
–
Error Register
Read Only
Optional
Unsigned 8
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
1003
0
Number of Errors
Read / Write
No
Unsigned 8
1 to FF
Standard Error field
Read Only
Unsigned 32
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
1005
–
COB-ID SYNC Message
Read / Write
No
Unsigned 32
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
1008
–
Manufacturer Device Name
Read Only
No
Visible string
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
1009
–
Manufacturer
Hardware Version
Read Only
No
Visible string
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
100A
–
Manufacturer
Software Version
Read Only
No
Visible string
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
Units
100C
–
Guard Time
Read / Write
No
Unsigned 16
1 ms
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
100D
–
Life Time Factor
Read / Write
No
Unsigned 8
Index (Hex.)
Subindex
Content
Access
PDO Mapping
Value Range
100E
–
Node Guarding Identifier
Read / Write
No