![YASKAWA U1000 Series Скачать руководство пользователя страница 530](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114530.webp)
B.3 Parameter Table
530
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
Note:
Fault trace (i.e., the fault history) is not kept when CPF00, CPF01, CPF06, CPF24, oFA00, oFb00, oFC00, Uv1, Uv2, or Uv3
occur.
U6-13
(7CAH)
Flux Position Detection
(sensor)
Monitors the value of the flux position detection (sensor).
10 V: 180 deg
-10 V: -180 deg
(-10 to +10 V)
0.1 deg
–
U6-14
(7CBH)
Flux Position Estimation
(observer)
Monitors the value of the flux position estimation.
10 V: 180 deg
-10 V: -180 deg
(-10 to +10 V)
0.1 deg
–
U6-18
(7CDH)
Speed Detection PG1 Counter
Monitors the number of pulses for speed detection (PG1).
10 V: 65536
1 pulse
–
U6-19
(7E5H)
Speed Detection PG2 Counter
Monitors the number of pulses for speed detection (PG2).
10 V: 65536
1 pulse
–
U6-20
(7D4H)
Frequency Reference Bias
(Up/Down 2)
Displays the bias value used to adjust the frequency reference.
10 V: Max frequency
0.1%
–
U6-21
(7D5H)
Offset Frequency
The total value of the offset frequencies d7-01, d7-02 and d7-03 selected with digital inputs 44
to 46 is displayed.
10 V: Max frequency
0.1%
–
U6-22
(62H)
Zero Servo Pulse Movement
Displays how far the rotor has moved from its last position in PG pulses (multiplied by 4).
10 V: No. of pulses
per revolution
(-10 to +10 V)
1 pulse
–
U6-25
(6BH)
Feedback Control Output
Output monitor for the ASR speed loop.
10 V: Motor
secondary rated
current
(-10 to +10 V)
0.01%
–
U6-26
(6CH)
Feed Forward Control Output
Output monitor for Feed Forward control.
10 V: Motor
secondary rated
current
(-10 to +10 V)
0.01%
–
U6-57
(7C4H)
Integrated Current Deviation
during Judging Polarity
Displays the deviation from the integrated current when judging motor polarity. If this value is
lower than 819, then increase the value set to n8-84. The value 8192 is equivalent to the motor
rated current.
No signal output
available
1
–
U6-80 to
U6-83
(7B0H to
7B3H)
Online IP Address
IP Address currently available; U6-80 is the most significant octet
No signal output
available
–
–
U6-84 to
U6-87
(7B4H to
7B7H)
Online Subnet
Subnet currently available; U6-84 is the most significant octet
No signal output
available
–
–
U6-88 to
U6-91
(7B8H to
7F1H)
Online Gateway
Gateway currently available; U6-88 is the most significant octet
No signal output
available
–
–
U6-92
(7F2H)
Online Speed
Link Speed
10: 10 Mbps
100: 100 Mbps
–
–
U6-93
(7F3H)
Online Duplex
Duplex Setting
0: Half
1: Full
–
–
U6-98
(7F8H)
First Fault
First Option Fault
–
–
–
U6-99
(7F9H)
Current Fault
Current Option Fault
–
–
–
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
No. (Addr.)
Name
Description
Analog Output
Level
Unit
Page
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
All Modes
All Modes
All Modes
All Modes
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes