Digital Operator Display
Task
rdEr
Error Reading Data
Cause
Possible Solutions
Failed while attempting to read parameter settings from the
drive.
Press and hold the READ key on the USB Copy Unit for at least one second to have the unit read parameters from the drive.
Digital Operator Display
Task
rEAd
Reading Parameter Settings (flashing)
Cause
Possible Solutions
Displayed while the parameter settings are being read onto the
USB Copy Unit.
Not an error.
Digital Operator Display
Task
vAEr
Voltage Class, Capacity Mismatch
Cause
Possible Solutions
The drive the parameters were copied from and the drive you
performing the Verify mode on have different electrical
specifications or are a different capacity.
Make sure electrical specifications and capacities are the same for both drives.
Digital Operator Display
Task
vFyE
Parameter settings in the drive and those saved to the copy function are not the same
Cause
Possible Solutions
Indicates that parameter settings that have been Read and
loaded onto the Copy Unit or Digital Operator are different.
To have parameters be the same, either write the parameters save on the USB Copy Unit or LCD digital operator onto the
drive, or Read the parameter settings on the drive onto the USB Copy Unit.
Digital Operator Display
Task
vrFy
Comparing Parameter Settings (flashing)
Cause
Possible Solutions
The Verify mode has confirmed that parameters settings on the
drive and parameters read to the copy device are identical.
Not an error.