u
Harmonic Filter Modules for Drive Models 4
o
0720 to 4
o
0930
Table A.9 Harmonic Filter Module Watt Loss
Drive Model
Normal Duty
Heavy Duty
Rated Amps
(A)
Heatsink
Loss (W)
Interior Unit
Loss (W)
Total Loss
(W)
Rated Amps
(A)
Heatsink
Loss (W)
Interior Unit
Loss (W)
Total Loss
(W)
EUJ71180
o
.
o
720
3268
27
3295
590
2411
27
2438
EUJ71181
o
.
o
900
3934
27
3962
720
2778
27
2806
EUJ71182
o
.
o
930
4149
27
4176
900
3934
27
3962
A.4 Drive Watt Loss Data
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
485
A
Specifications
Содержание U1000 iQpump Drive
Страница 705: ......