Alarm Register Contents
The table below shows the alarm codes that can be read out from MEMOBUS/Modbus register 007FH.
Table C.5 Alarm Register 007FH Contents
0083H
A/D Conversion Error (CPF02)
0233H
Sumcheck Error (oFb32)
0084H
PWM Data Fault (CPF03)
0234H
Comm. option timeout waiting for response (oFb33)
0087H
EEPROM Memory Data Error (CPF06)
0235H
MEMOBUS Timeout (oFb34)
0088H
Terminal Board Connection Error (CPF07)
0236H
Drive timeout waiting for response (oFb35)
0089H
EEPROM Serial Communication Fault (CPF08)
0237H
CI Check Error (oFb36)
008CH
RAM Fault (CPF11)
0238H
Drive timeout waiting for response (oFb37)
008DH
Flash Memory Circuit Exception (CPF12)
0239H
Control Command Selection Error (oFb38)
008EH
Watchdog Circuit Exception (CPF13)
023AH
Drive timeout waiting for response (oFb39)
008FH
Control Circuit Fault (CPF14)
023BH
Control Response Selection 1 Error (oFb40)
0091H
Clock Fault (CPF16)
023CH
Drive timeout waiting for response (oFb41)
0092H
Timing Fault (CPF17)
023DH
Control Response Selection 2 Error (oFb42)
0093H
Control Circuit Fault (CPF18)
023EH
Control Response Selection Error (oFb43)
0094H
Control Circuit Fault (CPF19)
0300H
Option Compatibility Error (oFC00)
0095H
Hardware fault at power up (CPF20)
0301H
Option not properly connected (oFC01)
0096H
Hardware fault at communication start up (CPF21)
0302H
Same type of option card already connected (oFC02)
0097H
A/D Conversion Fault (CPF22)
0305H
A/D Conversion Error (oFC05)
0098H
PWM Feedback Fault (CPF23)
0306H
Option Response Error (oFC06)
Alarm Code
Fault Name
Alarm Code
Fault Name
0001H
Undervoltage (Uv)
0020H
MEMOBUS/Modbus Test Mode Fault (SE)
0002H
Overvoltage (ov)
0022H
Motor Overheat (oH3)
0003H
Heatsink Overheat (oH)
0027H
PID Feedback Loss (FbL)
0004H
Drive Overheat (oH2)
0028H
PID Feedback Loss (FbH)
0005H
Overtorque 1 (oL3)
002AH
Drive Disabled (dnE)
0006H
Overtorque 2 (oL4)
002BH
PG Disconnected (PGo)
0007H
Run commands input error (EF)
0031H
SI-T3 Watchdog Error (E5)
0008H
Drive Baseblock (bb)
0032H
SI-T Station Number Setting Error (AEr)
0009H
External Fault 3, input terminal S3 (EF3)
0033H
SI-T Comm. Cycle Setting Error (CyC)
000AH
External Fault 4, input terminal S4 (EF4)
0034H
High Current Alarm (HCA)
000BH
External Fault 5, input terminal S5 (EF5)
0035H
Cooling Fan Maintenance Time (LT-1)
000CH
External Fault 6, input terminal S6 (EF6)
0036H
Capacitor Maintenance Time (LT-2)
000DH
External Fault 7, input terminal S7 (EF7)
0038H
SI-S EEPROM Error (EEP)
000EH
External Fault 8, input terminal S8 (EF8)
0039H
External Fault (input terminal S1) (EF1)
000FH
Cooling Fan Error (FAn)
003AH
External Fault (input terminal S2) (EF2)
0010H
Overspeed (oS)
003BH
Safe Disable Input (HbbF)
0011H
Excessive Speed Deviation (dEv)
003CH
Safe Disable Input (Hbb)
0012H
PG Disconnected (PGo)
003FH
PLC Alarm (PA1)
0014H
MEMOBUS/Modbus Communication Error (CE)
0040H
PLC Alarm (PA2)
0015H
Option Communication Error (bUS)
0041H
Output Voltage Detection Fault (voF)
0016H
Serial Communication Transmission Error (CALL)
0042H
IGBT Maintenance Time (90%) (TrPC)
001AH
Option Card External Fault (EF0)
0043H
Soft Charge Bypass Relay Maintenance Time (LT-3)
001BH
Motor Switch command input during run (rUn)
0044H
IGBT Maintenance Time (50%) (LT-4)
001DH
Serial Communication Transmission Error (CALL)
0045H
Braking Transistor Overload (boL)
001EH
Undertorque Detection 1 (UL3)
0047H
Input Phase Loss (PF)
001FH
Undertorque Detection 2 (UL4)
0071H
Undervoltage (Uv)
Fault Code
Fault Name
Fault Code
Fault Name
Содержание T1000A
Страница 4: ...4 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 32: ...1 5 Component Names 32 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 104: ...4 10 Test Run Checklist 104 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 334: ...7 5 Drive Replacement 334 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 362: ...A 6 Drive Derating Data 362 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...