B.3 Parameter Table
370
YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
n
b4: Timer Function
n
b5: PID Control
b3-10
(19AH)
Speed Search Detection
Compensation Gain
Sets the gain which is applied to the speed detected by Speed Estimation Speed Search before
the motor is reaccelerated. Increase this setting if ov occurs when performing Speed Search
after a relatively long period of baseblock.
Default: 1.05
Min: 1.00
Max: 1.20
b3-14
(19EH)
Bi-Directional Speed Search
Selection
0: Disabled (uses the direction of the frequency reference)
1: Enabled (drive detects which way the motor is rotating)
Default:
Min: 0
Max: 1
b3-17
(1F0H)
Speed Search Restart Current
Level
Sets the Speed Search restart current level as a percentage of the drive rated current.
Default: 150%
Min: 0%
Max: 200%
b3-18
(1F1H)
Speed Search Restart Detection
Time
Sets the time to detect Speed Search restart.
Default: 0.10 s
Min: 0.00 s
Max: 1.00 s
b3-19
(1F2H)
Number of Speed Search Restarts
Sets the number of times the drive can attempt to restart when performing Speed Search.
Default: 3
Min: 0
Max: 10
b3-24
(1C0H)
Speed Search Method Selection
0: Current Detection
1: Speed Estimation
3: Synchronous Operation (V/f)
Default: 0
Min: 0
Max: 3
b3-25
(1C8H)
Speed Search Wait Time
Sets the time the must wait between each Speed Search restart attempt.
Default: 0.5 s
Min: 0.0 s
Max: 30.0 s
b3-27
(1C9H)
Start Speed Search Select
Selects a condition to activate Speed Search Selection at Start (b3-01) or External Speed Search
Command 1 or 2 from the multi-function input.
0: Triggered when a Run command is issued (normal).
1: Triggered when an external baseblock is released.
Default: 0
Min: 0
Max: 1
<9> Default setting value varies by the drive model (o2-04).
<24> Default setting value is dependent on the drive model (o2-04) and the Drive Duty (C6-01).
<34> Default setting is determined by the control mode (A1-02).
No.(Addr.)
Name
Description
Setting
Page
b4-01
(1A3H)
Timer Function On-Delay Time
Used to set the on-delay and off-delay times for a digital timer output (H2-
=12). The output
is triggered by a digital input programmed to H1-
=18)
Default: 0.0 s
Min: 0.0 s
Max: 3000.0 s
b4-02
(1A4H)
Timer Function Off-Delay Time
Default: 0.0 s
Min: 0.0 s
Max: 3000.0 s
No.(Addr.)
Name
Description
Setting
Page
b5-01
(1A5H)
PID Function Setting
0: Disabled
1: Enabled (PID output becomes output frequency reference, deviation D controlled)
2: Enabled (PID output becomes output frequency reference, feedback D controlled)
3: Enabled (PID output added to frequency reference, deviation D controlled)
4: Enabled (PID output added to frequency reference, feedback D controlled)
Default: 0
Min: 0
Max: 4
b5-02
(1A6H)
Proportional Gain Setting (P)
Sets the proportional gain of the PID controller.
Default: 1.00
Min: 0.00
Max: 25.00
b5-03
(1A7H)
Integral Time Setting (I)
Sets the integral time for the PID controller.
Default: 1.0 s
Min: 0.0 s
Max: 360.0 s
No.(Addr.)
Name
Description
Setting
Page
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
OLV/PM
AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f
OLV
All Modes
All Modes
All Modes
All Modes
Содержание T1000A
Страница 4: ...4 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 32: ...1 5 Component Names 32 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 104: ...4 10 Test Run Checklist 104 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 334: ...7 5 Drive Replacement 334 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...
Страница 362: ...A 6 Drive Derating Data 362 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual...