This tab shows the synchronization properties of the IO controller. Here nothing can be
changed.
Here you can configure time-of-day master for time-of-day synchronization in the network.
NTP (
N
etwork
T
ime
P
rotocol) is used to implement a TCP/IP protocol for time-of-day syn-
chronization in networks. In the NTP mode the module sends out time-of-day queries at
regular intervals to all configured NTP servers. Based on the response from the servers,
the most reliable and most exact time-of-day is determined and used to synchronize the
time-of-day of the module. Configure with [Add] a NTP server and enter the update
interval. The time-of-day of the module is synchronized once within this interval.
9.7.3 Port 1
Shown is the short name "Port...". In the field Name another designation may be selected,
which is also shown in the configuration table At
comment
you may describe your entry
near more. The comment also appears in the configuration table.
Via the
port
address the diagnostics information of the IO controller may be accessed.
These parameters serve for the handling of the ports and should not be changed.
These parameters serve for the handling of the ports and should not be changed.
Synchronization
Time-of-day synchroniza-
tion
General
Addresses
Topology
Options
System 300S
+
Deployment Ethernet communication - PROFINET
Parameters - PROFINET IO controller > Port 1
HB140 | CPU | 315-4PN23 | en | 18-02
129
Содержание SPEED7 300S+ CPU 315PN
Страница 1: ...CPU 315 4PN23 Manual HB140 CPU 315 4PN23 en 18 02 System 300S SPEED7 CPU 315PN...
Страница 89: ...System 300S Deployment PtP communication Modbus Example communication HB140 CPU 315 4PN23 en 18 02 89...
Страница 155: ...Appendix System 300S Appendix HB140 CPU 315 4PN23 en 18 02 155...