6.1 Alarms Related to the Dynamic Brake Hardware Option Specifications
6.1.1 List of Alarms
6-2
6.1
Alarms Related to the Dynamic Brake Hardware Option Specifications
6.1.1
List of Alarms
This section gives the alarm names, alarm meanings, alarm stopping methods, alarm reset
possibilities, and alarm code outputs for alarms related to the dynamic brake hardware option
specifications.
Servomotor Stopping Method for Alarms
Refer to the standard SERVOPACK product manual for information on the motor stopping
method when an alarm occurs.
Alarm Reset Possibility
Yes: You can use an alarm reset to clear the alarm. However, this assumes that the cause of
the alarm has been removed.
No: You cannot clear the alarm.
List of Alarms
Alarm
Number
Alarm Name
Alarm Meaning
Servo-
motor
Stop-
ping
Method
Alarm
Reset
Possi-
ble?
Alarm Code
Output
ALO1 ALO2 ALO3
A.042
Parameter Combination
Error
•
The combination of some
parameters exceeds the
setting range.
•
The required parameters
(Pn001, Pn601, and
Pn604) have not been set.
Gr.1
No
H
H
H
A.730
Dynamic Brake Overload
When the dynamic brake was
applied, the rotational or lin-
ear kinetic energy exceeded
the allowable energy con-
sumption of the dynamic
brake resistor.
Gr.1
Yes
L
L
L