SIEP C730600 88F MECHATROLINK-III Technical Manual
45
PRM_WR Response
Byte
Response
Description
32
PRM_WR (02 (Hex.))
Command code
33
SUB_STAT
Refer to page
34
35
36
NO
The value (Lower) set in the command.
37
The value (Upper) set in the command.
38
SIZE
The value set in the command.
39
Reserved (0)
0 is set.
40
PARAMETER
The value set in the command.
0 is stored when the field is not used.
41
42
・
・
63
In the following status, an alarm is detected and the command goes into error.
Error
Response
Register Number Error
“
9
”
is set for CMD_ALM.
Bit Count Error
“
9
”
is set for CMD_ALM.
Data Setting Error
“
9
”
is set for CMD_ALM.
Write Mode Error
“
9
”
is set for CMD_ALM.
Writing Error during Under Voltage
“
9
”
is set for CMD_ALM.
Writing Error during Parameter Processing
“
9
”
is set for CMD_ALM.
◆
ALM_RD: 05 (Hex.) (Read Alarm and Warning Command)
The ALM_RD command reads the alarm or warning state. Refer to
ALM_RD: 05 (Hex.) (Read Alarm and
for more information on ALM_DATA. The command can be used in
communication phases 2 and 3. The current alarm or warning state is read from ALM_DATA as an alarm or
warning code. Refer to the drive manual for details about ALM_DATA.
ALM_RD Command
Byte
Command
Description
32
ALM_RD (05 (Hex.))
Command code
33
SUB_CTRL
Refer to page
34
35
36
ALM_RD_MOD
Specify the alarm or warning state. (Lower)
37
Specify the alarm or warning state. (Lower)
38
ALM_INDEX
Specify the alarm index.
The command is enabled when ALM_RD_MODE is 2. (Lower)
39
Specify the alarm index.
The command is enabled when ALM_RD_MODE is 2. (Upper)
40
Reserved (0)
Not used
41
42
・
・
63