Table 9.4 ALM_RD_MOD
Byte
ALM_RD_MOD = 0
ALM_RD_MOD = 1
ALM_RD_MOD = 2
4
00 (Hex.)
01 (Hex.)
02 (Hex.)
5
00 (Hex.)
00 (Hex.)
00 (Hex.)
6
-
-
ALM_INDEX (Lower)
7
-
-
ALM_INDEX (Upper)
8
U2-01
(Lower)
U3-01
(Lower)
ALM_INDEX = 0:
U2-01
(Lower)
ALM_INDEX ≠ 0: U3-(ALM_INDEX) (Lower)
9
U2-01
(Upper)
U3-01
(Upper)
ALM_INDEX = 0: U2-01 (Upper)
ALM_INDEX ≠ 0: U3-(ALM_INDEX) (Upper)
10
U2-02
(Lower)
U3-02
(Lower)
-
11
U2-02
(Upper)
U3-02
(Upper)
-
12
-
U3-03
(Lower)
-
13
-
U3-03
(Upper)
-
14
-
U3-04
(Lower)
-
15
-
U3-04
(Upper)
-
16
-
U3-05
(Lower)
-
17
-
U3-05
(Upper)
-
18
-
U3-06
(Lower)
-
19
-
U3-06
(Upper)
-
20
-
U3-07
(Lower)
-
21
-
U3-07
(Upper)
-
22
-
U3-08
(Lower)
-
23
-
U3-08
(Upper)
-
24
-
U3-09
(Lower)
-
25
-
U3-09
(Upper)
-
26
-
U3-10
(Lower)
-
27
-
U3-10
(Upper)
-
◆
ALM_CLR: 06 (Hex.) (Clear Alarm and Warning Command)
The ALM_CLR command clears the alarm or warning state after the cause has been removed. The command can
be used in communication phases 2 and 3.
This command changes the state of a slave station; it does not remove the cause of a fault. After the cause of the
alarm or warning has been removed, this command is then used to clear the status of the alarm or warning.
ALM_CLR Command
Byte
Command
Description
0
ALM_CLR (06 (Hex.))
Command code
1
WDT
Watchdog data
2
CMD_CTRL
Refer to page
3
4
ALM_CLR_MOD
0: Clears the status of present faults and alarms.
5
6
Reserved (0)
Not used
7
・
・
31