8 Object Dictionary
YASKAWA EUROPE GMBH
YEU SIEP C710616 86A - AC Drive A1000 Option Powerlink - Technical Manual
27
21F0 (Hex) - Configurable Output Object
Note:
This value can only be changed in Powerlink
pre-operational state.
The content of this object can be selected by linking them to drive MEMOBUS/Modbus registers.
2200 (Hex) - Motor Speed
This object can be used to monitor the motor speed. The value in object 2200 (Hex) is not filtered. Setting units are determined by o1-03.
The availability of the object content depends on the drive control mode. If the selected control mode does not support this monitor (equal to drive
monitor U1-05), the object value will be 0. Refer to the drive technical manual for details.
2210 (Hex) - DC Bus voltage
This object can be used to monitor the DC BUS voltage.
2220 (Hex) - Analog Input Monitor A1
This object can be used to display the analog input A1 level: 100% when input is 10 V.
2240 (Hex) - Analog Input Monitor A2
This object can be used to display the analog input A2 level: 100% when input is 10 V.
2260 (Hex) - Analog Input Monitor A3
This object can be used to display the analog input A3 level: 100% when input is 10 V.
Index (Hex)
Subindex
Content
Content
Access
PDO Mapping
Data Length
21F0
0
Number of entries
-
Read Only
No
Unsigned 8
1
Value of mapped drive register 1 and 2
Value: 0xAAAABBBB '
AAAA = MEMOBUS
register 1 address
BBBB = MEMOBUS
register 2 address
Read Only
Tx
Unsigned 32
2
MEMOBUS register address of content 1 and 2
Value: 0xAAAABBBB '
AAAA = MEMOBUS
register 1 address
BBBB = MEMOBUS
register 2 address
Reg. value=0xFFFF '
Mapping disabled.
Default: 0xFFFFFFFF
Read/Write
No
Unsigned 32
Index (Hex)
Subindex
Content
Default
Access
PDO Mapping
Data Length
2200
0
Number of Entries
-
Read Only
No
Unsigned 8
1
Motor Speed
-
Read Only
Tx
Unsigned 16
2
MEMOBUS/Modbus register address of content
0044 (Hex)
Read Only
No
Unsigned 16
Index (Hex)
Subindex
Content
Default
Access
PDO Mapping
Data Length
2210
0
Number of entries
-
Read Only
-
-
1
Value
1 V
Read Only
Tx
Unsigned 16
2
MEMOBUS/Modbus register address of content
0046 (Hex)
Read Only
No
Unsigned 16
Index (Hex)
Subindex
Content
Default
Access
PDO Mapping
Data Length
2220
0
Number of entries
-
Read Only
-
-
1
Value
0.1 %
Read Only
Tx
Unsigned 16
2
MEMOBUS/Modbus register address of content
004E (Hex)
Read Only
No
Unsigned 16
Index (Hex)
Subindex
Content
Default
Access
PDO Mapping
Data Length
2240
0
Number of entries
-
Read Only
-
-
1
Value
0.1 %
Read Only
Tx
Unsigned 16
2
MEMOBUS/Modbus register address of content
004F (Hex)
Read Only
No
Unsigned 16
Index (Hex)
Subindex
Content
Default
Access
PDO Mapping
Data Length
2260
0
Number of entries
-
Read Only
-
-
1
Value
0.1 %
Read Only
Tx
Unsigned 16
2
MEMOBUS/Modbus register address of content
0050 (Hex)
Read Only
No
Unsigned 16