Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5 - 6
5.1.2
Setting the Overtravel Limit Function
The overtravel limit function forces movable equipment parts to stop if they exceed
the allowable range of motion.
Using the Overtravel Function
To use the overtravel function, connect the overtravel limit switch input signal
terminals shown below to the correct pins of the servo amplifier CN1 connector.
Connect limit switches as shown below to prevent damage to the devices during
linear motion.
Drive
status with an input signal ON or OFF is shown in the following table.
Input P-OT CN1-42
Forward Run Prohibited
(Forward Overtravel)
Speed/Torque Control,
Position Control
Input N-OT CN1-43
Reverse Run Prohibited
(Reverse Overtravel)
Speed/Torque Control,
Position Control
Signal
State
Input Level
Description
P-OT
ON
CN1-42: low
Forward rotation allowed, (normal operation
status).
OFF
CN1-42: high
Forward run prohibited (reverse rotation
allowed).
N-OT
ON
CN1-43: low
Reverse rotation allowed, (normal operation
status).
OFF
CN1-43: high
Reverse run prohibited (forward rotation
allowed).
Forward rotation end
Reverse rotation end
Limit
switch
Servomotor
Servo Amplifier
CN1-42
CN1-43
N-OT
P-OT
Limit
switch
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......