Sigma II User’s Manual
Chapter 9: Inspection, Maintenance, and Troubleshooting
9 - 25
A.b1, A.b2
A.b1: Reference Speed Input Read Error
A.b2: Reference Torque Input Read Error
The alarm output, status, and remedy for A.b1 are the same as for A.b2.
Display and Outputs
Note:
OFF:
Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Output
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
OFF
OFF
Cause of the Problem
Solution
A
Error in reference read-in unit (A/
D Converter, etc.).
Reset alarm and restart opera-
tion.
B
Faulty reference read-in unit (A/D
Converter, etc.).
Replace servo amplifier.
C
Defective circuit board (1PWB).
Replace servo amplifier.
During servomotor operation.
At power ON.
A, B
A, B, C
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......