Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 47
Manual Gain Adjustment of Analog Monitor Output
Follow the procedure below to execute the manual gain adjustment of analog
monitor output.
Using the Hand-held Digital Operator
1.
Press the
DSPL/SET
key to select the auxiliary function mode.
2.
Select the parameter Fn00D.
Press the
Left Arrow
or
Right Arrow
key to select the digit.
Press the
Up Arrow
or
Down Arrow
key to change the value.
3.
Press the
DATA/SHIFT
key, and the display will be as shown below.
4.
Press the
DSPL/SET
key. Each time the
DSPL/SET
key is pressed, the monitor
output will toggle between the displays for the two channels shown below.
5.
Press the
Left Arrow
or
Right Arrow
key to display the analog monitor
gain parameter. Pressing the
Left Arrow
or
Right Arrow
key again will
return to the display shown above in step 3 or 4.
6.
Press the
Up Arrow
or
Down Arrow
key to adjust the gain for the analog
monitor output.
7.
When the gain adjustment has been completed for the two channels, press the
DATA/ENTER
key to return to the auxiliary function mode display.
This completes the manual gain adjustment of the analog monitor output.
DSPL/SET Key
Displayed
Alternately
Left Cursor Key
(Right Cursor Key)
Data Display
Displayed
Alternately
Data Setting Change
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......