Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 34
Using the Built-in Panel Operator
1.
Press the
MODE/SET
key to select the auxiliary function mode.
2.
Press the
Up Arrow
or
Down Arrow
key to select the parameter Fn006.
3.
Press the
DATA/SHIFT
key for a minimum of one second, and the display will
be as shown below.
4.
Press the
MODE/SET
key to clear the alarm traceback data. The following
display will flash for one second, and, after the alarm traceback data is cleared,
the display will return to the one shown above in step 3.
5.
Press the
DATA/SHIFT
key for a minimum of one second to return to the
parameter code display.
This completes the alarm traceback data clearing procedure.
7.2.6
Checking the Motor Model
Set the parameter Fn011 to select the Motor Model Check Mode. This mode is used
for motor maintenance, and can also be used to check the special (Y-specification)
codes of the servo amplifiers.
Follow the procedure below to check the motor model.
Using the Hand-held Digital Operator
1.
Press the
DSPL/SET
key to select the auxiliary function mode.
2.
Select the parameter Fn011.
Press the
Left Arrow
or
Right Arrow
key to select the digit.
SGDM-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Flashing for
one second
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......