Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 32
Using the Built-in Panel Operator
1.
Press the
MODE/SET
key to select the auxiliary function mode.
2.
Press the
Up Arrow
or
Down Arrow
key to select the parameter Fn00B.
3.
Press the
MODE/SET
key for a minimum of one second, and the display will be
as shown below. The manual adjustment mode for the torque reference offset
will be entered.
4.
Turn ON the Servo ON (/S-ON) signal. The display will be as shown below.
5.
Press the
DATA/SHIFT
key for less than one second, to display the torque
reference offset amount.
6.
Press the
Up Arrow
or
Down Arrow
key to adjust the offset amount,
(Adjustment of torque reference offset).
7.
Press the
DATA/SHIFT
key for less than one second, and the display will be as
shown in the above step 4.
8.
Press the
DATA/SHIFT
key to return to the auxiliary function mode.
This completes the torque reference offset manual adjustment.
SGDM-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......