Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 8
7.1.6
Operation in Parameter Setting Mode
Functions can be selected or adjusted by setting parameters. There are two types of
parameters that can be set. One type requires value setting and the other requires
function selection. These two types use different setting methods.
•
With value setting, a parameter is set to a value within the specified range of the
parameter.
•
With function selection, the functions allocated to each digit of the
seven-segment LED panel indicator (five digits) can be selected.
See
Appendix B List of Parameters.
Changing Parameter Settings
The parameter settings can be used to change parameter data. Check the permitted
range of the parameters in
Appendix B List of Parameters
, before changing the data.
The example below shows how to change parameter Pn507 from 100 to 85.
Using the Hand-held Digital Operator
1.
Press the
DSPL/SET
key to select the parameter setting mode.
2.
Select the parameter number to set. (Pn507 is selected in this example.)
Press the
Left Arrow
or
Right Arrow
key to select the digit. The
selected digit will flash.
Press tthe
Up Arrow
or
Down Arrow
key to change the value.
3.
Press the
DATA/ENTER
key to display the current data for the parameter
selected at step 2.
4.
Change the data as needed (to 85, in this example).
Press the
Left Arrow
or
Right Arrow
key to select the digit. The selected
digit will flash.
Press the
Up Arrow
or
Down Arrow
key to change the value.
Continue pressing the key until “00085” is displayed.
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......