Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 4
7.1.3
Resetting Servo Alarms
Servo alarms can be reset using the digital operator.
Using the Hand-held Digital Operator
Press the
RESET
key in status display mode.
Using the Built-in Panel Operator
Press the
Up Arrow
AND
Down Arrow
keys together in status display mode.
The alarm can be reset with CN1-44, or /ALM-RST signal input. Refer to
5.5.1
Using Servo Alarm and Alarm Code Outputs.
The servo alarm will be reset if the control power supply is turned OFF.
• If an alarm is ON, reset the alarm after eliminating the cause of the alarm first. Refer to
9.2 Troubleshooting.
SGDM-
MODE/SET DATA/
SERVOPACK
200V
YASKAWA
Built-in Panel Operator
Key
Name
Function
Up Arrow
Key
• Press this key to set parame-
ters or display the set values of
parameters.
• Press the
Up Arrow
key to
increase the set value.
• Press the
Down Arrow
key to
decrease the set value.
• Press the
Up
and
Down Arrow
keys together to reset a servo
alarm.
Down Arrow
Key
MODE/SET
Key
Press this key to select the status
indicator mode, auxiliary function
mode, parameter setting mode, or
monitor mode.
DATA/SHIFT
Key
• Press this key to set each
parameter or display the set
value of each parameter.
• This key is used for selecting
the editing (flashing) digit or
data setting.
MODE/SET
DATA/
IMPORTANT
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......