Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-131
Speed Related Parameters When a Direct-drive Motor is Connected
As the maximum speed of SGMCS servomotor is approximately 1/10 of standard
SGM H servomotor, the unit of parameter setting is changed to 1/10 of the
standard.
When a SGMCS servomotor is connected, the SERVOPACK changes the setting
unit automatically as shown in the following table.
Also, when a motor with a maximum speed is 500 rpm or less is connected, the
SERVOPACK changes the setting unit to 1/10 of the standard automatically.
Besides the parameter, the speed setting for the auxiliary function Fn003 "Zero-point
search mode" is fixed to 6 [rpm] when a direct-drive servomotor is connected.
Also, the analog monitor output units are changed as shown in the shaded areas in the
table below.
Parameters
No.
Name
Units
Setting
Range
Factory
Setting
Direct Drive servomotor
or servomotor whose maximum
speed is 500 rpm or less
Others
Pn301
Speed 1
0.1 rpm
rpm
0 to 10000
100
Pn302
Speed 2
0.1 rpm
rpm
0 to 10000
200
Pn303
Speed 3
0.1 rpm
rpm
0 to 10000
300
Pn304
JOG
Speed
0.1 rpm
rpm
0 to 10000
500
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......