Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-125
5.8.6
Reactor for Harmonic Suppression
SGDH servo amplifiers have DC reactor connection terminals for power supply
harmonic suppression.
Connecting a DC Reactor
The DC reactor is connected in series to the rectifier circuit’s output side. Refer to
3.2 Servo Amplifier Internal Block Diagrams.
At the time of shipping, the servo amplifier’s (+)1 and (+)2 are short-circuited.
Remove the lead wire between the two terminals and connect the DC reactor.
Servo amplifier
DC reactor
⊕
1
⊕
2
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......