Using the Servo ON Input Signal (/S-ON)
The basic use and wiring procedure for the Servo ON (/S-ON) input signal
(sequence input signal) is described below. Use this signal to forcibly turn OFF the
servomotor from the host controller.
This signal is used to turn the servomotor ON and OFF.
Set the following parameter to 7 if the /S-ON signal will not be used.
Input /S-ON CN1-40
Servo ON
Speed/Torque Control,
Position Control
CN1-40
State
Status
Result
ON
Closed or low level
Turns ON the servomotor: operates
according to signal input.
This is the default state.
OFF
Open or high level
Servomotor cannot operate.
Do not turn OFF the servomotor while it is
operating except in an emergency.
•
Do not use the Servo ON (/S-ON) signal to start or stop the motor. Always use an input reference
signal, such as Speed Reference to start or stop the servomotor.
Doing so will shorten the life of the servo amplifier.
Parameter
Signal
Setting
Description
Pn50A.1
/S-ON Signal Mapping
Default Setting: 0
Speed/Torque Control,
Position Control
+24V
CN1-47
CN1-40
7mA
0V
Servo amplifier
I/O power supply
Photo
coupler
Host controller
/S-OUT
+24V
IN
3.3k
Ω
CAUTION
Servo amplifier
0V
CN-40
(/S-ON)
The external short-circuit wiring shown
in the figure can be omitted if the Servo ON
(/S-ON) input is not used.
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......