Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5 - 18
Note:
The noise margin of the input signal will decrease if the reference pulse is provided by an
open-collector output. Set parameter Pn200.3 to 1 if the position drifts due to noise.
Selecting a Reference Pulse Form
Use the following parameters to select the reference pulse form used.
The servomotor only rotates at an angle proportional to the input pulse.
Set reference pulse form input to the servo amplifier from the host controller.
Input PULS CN1-7
Reference Pulse Input
Position Control
Input /PULS CN1-8
Reference Pulse Input
Position Control
Input SIGN CN1-11
Reference Code Input
Position Control
Input /SIGN CN1-12
Reference Code Input
Position Control
Parameter
Signal
Setting Range
Control Mode
Pn200.0
Reference Pulse Form
Default Setting: 0
Position Control
Servo Amplifier
+12V
Photocoupler
/PULS
PULS
PL1
Approx.
9mA
Tr1
ON: 1.5V maximum
/SIGN
SIGN
PL2
/CLR
CLR
PL3
P represents twisted pair wires
Host controller
P
P
P
150
Ω
CN1-7
CN1-8
CN1-11
CN1-12
CN1-15
CN1-14
CN1-3
CN1-1
CN1-18
CN1-13
1k
Ω
Servo Amplifier
CN1-7
PULS
Position
reference
pulse
CN1-11
SIGN
Host
controller
Содержание SGMAH
Страница 1: ...Sigma II Series Servo System User s Manual...
Страница 2: ......
Страница 4: ...ii This page intentionally left blank...
Страница 6: ...iv This page intentionally left blank...
Страница 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Страница 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Страница 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Страница 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Страница 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Страница 487: ......