4.3 FT82 SERVOPACK with MECHATROLINK-III Communications References
4.3.2 List of MECHATROLINK-III Common Parameters
4-106
4.3.2
List of MECHATROLINK-III Common Parameters
The following table lists the common MECHATROLINK-III parameters. These common parame-
ters are used to make settings from the host controller via MECHATROLINK communications.
Do not change the settings with the Digital Operator or any other device.
Parameter
No.
Size
Name
Setting Range
Setting Unit
[Resolution]
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
01
PnA02
4
Encoder Type Selec-
tion (read only)
0h or 1h
–
–
All
–
Devi
ce in
for
m
atio
n
02
PnA04
4
Motor Type Selection
(read only)
0h or 1h
–
–
All
–
03
PnA06
4
Semi-closed/Fully-
closed Selection
(read only)
0h or 1h
–
–
All
–
04
PnA08
4
Rated Motor Speed
(read only)
0h to
FFFFFFFFh
1 min
-1
–
All
–
05
PnA0A
4
Maximum Output
Speed (read only)
0h to
FFFFFFFFh
1 min
-1
–
All
–
06
PnA0C
4
Speed Multiplier
(read only)
-1,073,741,823
to
1,073,741,823
–
–
All
–
07
PnA0E
4
Rated Torque
(read only)
0h to
FFFFFFFFh
1 N
m
–
All
–
08
PnA10
4
Maximum Output
Torque (read only)
0h to
FFFFFFFFh
1 N
m
–
All
–
09
PnA12
4
Torque Multiplier
(read only)
-1,073,741,823
to
1,073,741,823
–
–
All
–
0A
PnA14
4
Resolution
(read only)
0h to
FFFFFFFFh
1 pulse/rev
–
Rotary
–
Continued on next page.
0000h
Absolute encoder
0001h
Incremental encoder
0000h
Rotary Servomotor
0001h
Linear Servomotor
0000h
Semi-closed
0001h
Fully-closed