5 Operation
5.10.2 Warning Output Signal (/WARN)
5-76
(3) Alarm Reset Method
If a servo alarm (ALM) occurs, use one of the following methods to reset the alarm after eliminating the cause
of the alarm.
The /ALM-RST signal will not always reset linear scale-related alarms. If an alarm cannot be reset with /
ALM-RST, cycle the control power supply.
Resetting Alarms by Turning ON the /ALM-RST Signal
Resetting Alarms Using the Panel Operator
Simultaneously press the UP and the DOWN Keys on the panel operator. For details, refer to
.
Resetting Alarms Using the Digital Operator
Press the ALARM RESET Key on the digital operator. For details, refer to
-V Series User’s Manual, Opera-
tion of Digital Operator
(No.: SIEP S800000 55).
5.10.2
Warning Output Signal (/WARN)
This signal is for a warning issued before the occurrence of an alarm.
Refer to
(1) Signal Specifications
Note: Use parameter Pn50F.3 to allocate the /WARN signal for use. For details, refer to
(2) Related Parameters
Set the output method for alarm codes in Pn001.3.
For details on alarm codes, refer to
(2) Alarm Code Output Signals (ALO1, ALO2, and ALO3)
of
Alarm Output Signal (ALM) and Alarm Code Output Signals (ALO1, ALO2, and ALO3)
For details on warning codes, refer to
Be sure to eliminate the cause of the alarm before resetting it.
If the alarm is reset and operation continued without eliminating the cause of the alarm, it
may result in damage to the equipment or fire.
Type
Signal Name
Connector Pin Num-
ber
Meaning
Input
/ALM-RST
CN1-44
Alarm reset
Type
Signal
Name
Connector Pin
Number
Setting
Meaning
Output
/WARN
Must be allocated
ON (closed)
Warning status
OFF (open)
Normal status
Parameter
Meaning
When Enabled
Classification
Pn001
n.0
Outputs alarm codes alone for alarm codes ALO1,
ALO2, and ALO3.
After restart
Setup
n.1
Outputs both alarm and warning codes for alarm codes
ALO1, ALO2, and ALO3, and outputs an alarm code
when an alarm occurs.
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...