www.dadehpardazan.ir 88594014-15
5 Operation
5.7.2 Switching Other Than Internal Set Speed Control (Pn000.1 = 7, 8 or 9)
5-62
5.7.2
Switching Other Than Internal Set Speed Control (Pn000.1 = 7, 8 or 9)
Use the following signals to switch control methods when Pn000.1 is set to 7, 8, or 9. The control methods
switch depending on the signal status as shown below.
(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)
(2) Changing Input Signal Allocations (Pn50A.0 = 1)
5.7.3
Switching Other Than Internal Set Speed Control (Pn000.1 = A or B)
Use the following signals to switch control methods when Pn000.1 is set to A or B. The control methods
switch depending on the signal status as shown below.
(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)
(2) Changing Input Signal Allocations for Each Signal (Pn50A.0 = 1)
Type
Signal
Name
Connector
Pin Number
Setting
Pn000.1 Setting and Control Method
n.
7
n.
8
n.
9
Input
/P-CON
CN1-41
ON (closed)
Speed
Force
Speed
OFF (open)
Position
Position
Force
Type
Signal
Name
Connector
Pin Number
Setting
Pn000.1 Setting and Control Method
n.
7
n.
8
n.
9
Input
/C-SEL
Must be
allocated
ON (closed)
Speed
Force
Speed
OFF (open)
Position
Position
Force
Type
Signal
Name
Connector
Pin Number
Setting
Pn000.1 Setting and Control Method
n.
A
n.
B
Input
/P-CON
CN1-41
ON (closed)
Speed control with
zero clamp function
Position control with
reference pulse
inhibit function
OFF (open)
Speed
Position
Type
Signal
Name
Connector
Pin Number
Setting
Pn000.1 Setting and Control Method
n.
A
n.
B
Input
/ZCLAMP
Must be
allocated
ON (closed)
Speed control with
zero clamp function
OFF (open)
Speed
/INHIBIT
ON (closed)
Position control with
reference pulse
inhibit function
OFF (open)
Position
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...