To update drive parameters on a Yaskawa drive, follow these instructions.
From the display panel:
Press the Mode/Set key until you see the parameter set needing changed (example: Pn0001). Use the Up/Down
arrow keys to move through the list and select the parameter number to change.
Press the Data key to view the current parameter setting (have to hold it for a second or two). Record this
number so you know your reference point.
Press the up/down arrow to change the setting. Press and hold the Data key when done.
Repeat for other parameters.
Power cycle the drive when done programming.
Through the Software with Tuning/Programming cable:
Go the Start Menu on the control and search "SigmaWin". Open "S English Edition".
Click Online button:
Select search box on the USB tab with the "Sigma Five" drive selected:
Updating Yaskawa Parameters