5.2 Servomotor Main Circuit Cables
5.2.2 Servomotor Main Circuit Cables for Servomotors with Holding Brakes
5
Cable
s
and U
s
er
-A
ss
embled Wiring Material
s
for
SG
M7P Rotary
S
ervomotor
s
5-5
5.2.2
Servomotor Main Circuit Cables for Servomotors with
Holding Brakes
Selection Table
*1.
Replace the boxes (
) in the order number with the cable length (03, 05, 10, 15, 20, 30, 40, or 50).
*2.
Use Flexible Cables for moving parts of machines, such as robots.
*3.
The recommended bending radius (R) is 90 mm or larger.
Note: If the length of the Servomotor Main Circuit Cable exceeds 20 m, the intermittent duty zone in the torque-
motor speed characteristics will become smaller because the voltage drop increases.
Lead Structure
Note: Refer to the following sections for information on connector and cable manufacturers and order numbers.
5.3.1 Servomotor Connector Kits
5.3.2 Cables without Connectors
Wiring Specifications
Note: There is no polarity for the connection to the holding brake.
Servomotor Model
Length (L)
Order Number
*1
Standard Cable
Flexible Cable
*2, *3
SGM7P-01
100 W
3 m, 5 m, 10 m, 15 m,
20 m, 30 m, 40 m, and
50 m
JZSP-CSM11-
-E
JZSP-CSM31-
-E
SGM7P-02 or -04
200 W or 400 W
JZSP-CSM12-
-E
JZSP-CSM32-
-E
SGM7P-08
750 W
JZSP-CMM10-
-E
JZSP-CMM11-
-E
SGM7P-15
1.5 kW
JZSP-CMM30-
-E
Note: Flexible Cables are not
available.
For 100 W to 400 W
For 750 W or 1.5 kW
For 100 W to 400 W
For 750 W or 1.5 kW
50 mm
L
Motor end
S
ERVOPACK end
M4 crimped terminal
L
50 mm
Motor end
S
ERVOPACK end
M4 crimped terminal
Pin
S
ignal
S
ignal
Wire Color
1
2
3
4
5
6
S
ervomotor Connector
Pha
s
e U
Pha
s
e V
Pha
s
e W
FG
Brake
Brake
Brake
Brake
Pha
s
e U
Pha
s
e V
Pha
s
e W
FG
Red
White
Blue
Green/yellow
Black
Black
S
ERVOPACK Lead
s
Pin
S
ignal
S
ignal
Wire Color
1
2
3
4
5
6
S
ervomotor Connector
FG
Pha
s
e W
Pha
s
e V
Pha
s
e U
Brake
Brake
Brake
Brake
FG
Pha
s
e W
Pha
s
e V
Pha
s
e U
Green/yellow
Blue
White
Red
Black
Black
S
ERVOPACK Lead
s