13.4 Utility Function (Fn
) Operations on the Panel Operator
13.4.21 Display SERVOPACK and Servomotor IDs (Fn01E)
13-28
13.4.21 Display SERVOPACK and Servomotor IDs (Fn01E)
This function cannot be executed from the Panel Operator on the SERVOPACK.
13.4.22 Display Servomotor ID from Feedback Option Module
(Fn01F)
This function cannot be executed from the Panel Operator on the SERVOPACK.
13.4.23 Set Absolute Linear Encoder Origin (Fn020)
Refer to the following section for information on this utility function other than the procedure.
5.18.1 Setting the Origin of the Absolute Linear Encoder
5
Wait for a period of time and then press the
MODE/
SET
Key again to complete vibration detection and
updating the setting. This will enable the setting. If the
setting is completed normally,
donE
will be displayed.
If there was an error in making the setting,
Error
will be
displayed.
6
Press the
DATA/SHIFT
Key for approximately one sec-
ond to return the display to
Fn01b
.
Continued from previous page.
Step
Panel Display after
Operation
Keys
Operation
MODE/SET
DATA/
MODE/SET
DATA/
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Utility Function
Mode.
2
Press the
UP
Key or
DOWN
Key to display
Fn020
.
3
Press the
DATA/SHIFT
Key for approximately one sec-
ond. The display shown at the left will appear.
4
Continue pressing the
UP
Key until
0SET5
is dis-
played.
Note: If you make a mistake during key operations,
no_oP
will
flash on the display for approximately one second and
then
Fn000
will be displayed again.
5
Press the
MODE/SET
Key to set the origin of the
absolute linear encoder.
When the setting has been completed,
donE
will flash
on the display, and then the display shown on the left
will appear again.
6
Press the
DATA/SHIFT
Key for approximately one sec-
ond to return the display to
Fn020
.
7
To enable the change to the settings, turn the power supply to the SERVOPACK OFF and ON again.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/