4.4 Wiring Servomotors
4.4.4 Wiring the SERVOPACK to the Holding Brake
4-32
4.4.4
Wiring the SERVOPACK to the Holding Brake
*
Install the surge absorber near the brake terminals on the Servomotor.
•
If you use a Rotary Servomotor, select a Surge Absorber according to the brake current and
brake power supply. Refer to the following manual for details.
Σ
-7-Series Peripheral Device Selection Manual (Manual No.: SIEP S800001 32)
•
After the Surge Absorber is connected, check the brake operation delay time in your applica-
tion. The Surge Absorber may affect the brake operation delay time.
Configure the relay circuit to activate the holding brake for an emergency stop.
•
The /BK (Brake) signal cannot be used with the default settings. You must allocate the output
signal. Refer to the following section for details.
Allocating the /BK (Brake) Signal
•
If you use a 24-V brake, install a separate power supply for the 24-VDC power supply from
other power supplies, such as the one for the I/O signals of the CN1 connector. If the power
supply is shared, the I/O signals may malfunction.