6.1 I/O Signal Allocations
6.1.7 /V-CMP (Speed Coincidence Detection) Signal
6
Application Function
s
6-11
6.1.7
/V-CMP (Speed Coincidence Detection) Signal
The /V-CMP (Speed Coincidence Output) signal is output when the Servomotor speed is the
same as the reference speed. This signal is used, for example, to interlock the SERVOPACK
and the host controller. You can use this output signal only during speed control.
The /V-CMP signal is described in the following table.
Note: You must allocate the /V-CMP signal to use it. Use Pn50E = n.
X
(/V-CMP (Speed Coincidence Detec-
tion Output) Signal Allocation) to allocate the signal to connector pins.
Refer to the following section for details on allocations.
You can set the speed detection width for the /V-CMP signal in Pn503 (Speed Coincidence
Detection Signal Output Width) for a Rotary Servomotor or in Pn582 (Speed Coincidence
Detection Signal Output Width) for a Linear Servomotor.
•
Rotary Servomotors
The signal is output when the difference between the reference speed and motor speed is
equal or less than the setting.
•
Linear Servomotors
The signal is output when the difference between the reference speed and motor speed is
equal or less than the setting.
Type
Signal
Connector Pin No.
Signal Status
Meaning
Output
/V-CMP
Must be allocated.
ON (closed)
The speed coincides.
OFF (open)
The speed does not coincide.
Pn503
Speed Coincidence Detection Signal Output Width
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 100
1 min
-1
10
Immediately
Setup
If Pn503 is set to 100 and the speed reference is 2,000 min
-1
, the signal would be output
when the motor speed is between 1,900 min
-1
and 2,100 min
-1
.
Pn582
Speed Coincidence Detection Signal Output Width
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 100
1 mm/s
10
Immediately
Setup
If Pn582 is set to 100 and the speed reference is 2,000 mm/s the signal would be output
when the motor speed is between 1,900 mm/s and 2,100 mm/s.
Speed
Example
Pn50
3
S
peed reference
The /V-CMP
s
ignal i
s
output when the motor
s
peed i
s
in
the area between the dotted line
s
.
Motor
s
peed
Speed
Example
Pn582
S
peed reference
The /V-CMP
s
ignal i
s
output when the motor
s
peed i
s
in
the area between the dotted line
s
.
Motor
s
peed