![YASKAWA SGD7S-1R9D Скачать руководство пользователя страница 430](http://html1.mh-extra.com/html/yaskawa/sgd7s-1r9d/sgd7s-1r9d_product-manual_3461204430.webp)
13.9 Touch Probe
13.9.2 Example of Execution Procedure for a Touch Probe
13-24
13.9.2
Example of Execution Procedure for a Touch Probe
•
Single Trigger Mode (60B8 hex bit 1 = 0 or bit 9 = 0)
•
Continuous Trigger Mode (60B8 hex bit 1 = 1 or bit 9 = 1)
60B8 hex bit 0
(bit 8)
60B8 hex bit 4
(bit 12)
60B9 hex bit 0
(bit 8)
60B9 hex bit 1
(bit 9)
60BA hex
(60BC hex)
Probe input
Latching started.
Latching started.
1
2
3
Latched position 1
Latched position 3
60B8 hex bit 0
(bit 8)
60B8 hex bit 4
(bit 12)
60B9 hex bit 0
(bit 8)
60B9 hex bit 1
(bit 9)
60B9 hex bit 7
(bit 15)
60BA hex
(60BC hex)
Probe input
Latching started.
Latched position 1
Latched position 2
1
2
3
Latched position 3