12.1 Data Logging
12.1.5 Analyzing Log Data
12-14
12.1.5
Analyzing Log Data
This section describes how the log data is formatted when viewed on a PC.
CSV File Format
This example shows how log data that is stored in the CSV format appears when it is opened in
Microsoft Excel.
•
Header Details
*
These items may not be given depending on the settings in the MPE720. Refer to the following section for details.
No.
Item
Description
Corresponding Item in MPE720
HeaderSize
Gives the size of the header that is
appended to the file.
−
*
ScanType
The type of scan where the data was
obtained (high-speed scan or low-
speed scan) is displayed.
Sampling period
on the Format Dialog
Box.
*
ScanTime
Gives the data sampling period.
*
Register
Gives the registers specified in the data
settings.
Registered register name
on the Format
Dialog Box.
*
ProgramName
Gives the program name specified in
the data settings.
Program
on the Format Dialog Box.
*
No.
Gives the number of the data that was
sampled.
Data No.
on the Format Dialog Box.
*
DATE/TIME
Gives the time down to the seconds
when the data was sampled.
This is a running value from 1970,
which is the lower limit of the calendar
setting.
DATE/TIME
on the Format Dialog Box.