8 Set-up Procedure for Semi-closed Loop Control
8.2.3 Sigma-5 SERVOPACK Set-up with Linear Motor
8-10
*1 these settings are dependent on the applications
*2 in case of Pn080.0=1 (Disables hall sensor), the setting is not required
*3 this is only required when using Sigma-1 motors
8.2.3
Sigma-5 SERVOPACK Set-up with Linear Motor
According to applications, these parameters should be set for the correct operation of Sigma-5 with the option
modules.
Pn482
Polarity Detection Speed Loop Integral Time
[0.01 msec]
30.00
*1
O
Immediately
Pn486
Polarity Detection Command Accel/Decel Time
[msec]
25
*1
O
Immediately
Pn487
Polarity Detection Constant Speed Time [msec]
0
*1
O
Immediately
Pn488
Polarity Detection Command Waiting Time
[msec]
100
*1
O
Immediately
Pn490
Polarity Detection Load Level [%]
100
*1
O
Immediately
Pn493
Polarity Detection Command Speed [min
-1
]
50
*1
O
Immediately
Pn494
Polarity Detection Range [0.001 rev]
0.250
*1
O
Immediately
Pn495
Polarity Detection Confirmation Torque Com-
mand [%]
100
*1
O
Immediately
Pn498
Polarity Detection Allowable Error Range [deg.] 10
*1
O
Immediately
Pn587
Polarity Detection for Absolute Scale Selection
-
-
-
Immediately
0
0
Does not detect polarity
0
*1
O
Immediately
1
Detects polarity
Parameter
Function
Default
Value
Required
value
Cat.
When enabled
No.
Dig.
Parameter
Function
Default
Value
Required
value
Cat.
When enabled
No.
Dig.
Pn000
Basic Function Select Switch 0
-
-
-
-
0
Direction Selection
0
*1
O
After restart
0
Forward command for forward direction
1
Forward command for reverse direction
Pn002
Application Function Select Switch 2
-
-
-
-
2
Absolute Encoder Usage
0
*1
O
After restart
0
Uses absolute encoder as an absolute
encoder
1
Uses absolute encoder as an incremental
encoder
Pn00B
Application Function Select Switch B
-
-
-
-
3
Feedback Option Module Usage
0
*1
M
After restart
0
Uses CN2 for external encoder feedback
1
Uses FB option for motor encoder feed-
back