8.2 Setup Procedure
8-9
8
Set-up Procedure for Semi-closed Loop Control
8.2.2
Sigma-5 SERVOPACK Set-up with Rotary Motor
According to applications, these parameters should be set for the correct operation of Sigma-5 with the option
modules.
Parameter
Function
Default
Value
Required
value
Cat.
When enabled
No.
Dig.
Pn000
Basic Function Select Switch 0
-
-
-
-
0
Direction Selection
0
*1
O
After restart
0
Forward command for forward direction
1
Forward command for reverse direction
Pn002
Application Function Select Switch 2
-
-
-
-
2
Absolute Encoder Usage
0
*1
O
After restart
0
Uses absolute encoder as an absolute
encoder
1
Uses absolute encoder as an incremental
encoder
3
External Encoder Usage
0
0
M
After restart
0
Do not use external encoder
1
Uses external encoder in forward rotation
direction
2
Reserved (Do not change.)
3
Uses external encoder in reversed rotation
direction
4
Reserved (Do not change.)
Pn00B
Application Function Select Switch B
-
-
-
-
3
Feedback Option Module Usage
0
*1
M
After restart
0
Used for external encoder feedback
1
Used for motor encoder feedback
Pn080
Application Function Select Switch B
-
-
-
-
0
Hall Sensor Selection
0
*1
O
After restart
0
Enables hall sensor
1
Disables hall sensor
1
Motor Phase Selection
0
*1
O
After restart
0
Sets positive position feedback as phase
sequence of U, V, W
1
Sets negative position feedback as phase
sequence of U, V, W
Pn081
Application Function Select Switch 81
-
-
-
-
1
Encoder Pulse Output Usage
0
*1
O
After restart
0
Enables the pulse output function (Pn281)
1
Disables the pulse output function
2
Coordination Setting between Origin and U-
phase position
0
*2
O
After restart
0
Both positions are same
1
The positions are different
3
Hall Sensor Signal Inversion
0
*1
O
After restart
0
Does not inverse the signals (Pos-Logic)
1
Inverses the signals (Neg-Logic)
Pn212
Encoder Output pulses [Pulse/Rev]
2048
*1
O
After restart
Pn481
Polarity Detection Speed Loop Gain [0.1 Hz]
40.0
*1
O
Immediately
Содержание S-V Seres
Страница 16: ...xvi ...
Страница 20: ...1 Checking Products 1 4 1 3 Nameplate Location OFB03A Nameplate Ratings Nameplate Model no OFB03A 1 ...
Страница 56: ...8 Set up Procedure for Semi closed Loop Control 8 2 3 Sigma 5 SERVOPACK Set up with Linear Motor 8 12 ...
Страница 62: ...9 Motor and Scale Parameter File 9 2 2 Scale Parameters 9 6 ...