2-5
183523-1CD
183523-1CD
2
Installation
2.3 Positioner Installation
RM2-755-RDR Postioner
2.3.1.1 Location
Make sure Positioner is installed, with the following conditions:
• Ambient Temperature: 0° to +45°C
• Humidity: 20% to 80% RH (non-condensing)
• Free from dust, soot or water
• Free from corrosive gas or liquid, or explosive gas
• Free from excessive vibration (Vibration acceleration: 4.9m/s2 [0.5G]
or less)
• Free from large electrical noise (plasma)
• Flatness for installation: 0.5mm or less.
• Ensure appropriate space for equipment reviewing
,
1 “Positioner Technical Specifications” on page 4-1
and any other
additional documentation as required.
CAUTION
• Install the Positioner in a location where the Positioner with a jig
does not hit against anything such as the wall or the safeguarding
Failure to observe this caution may result in damage.
25 of 104