5.1 Debugging Ladder Programs
5.1.3 Watch Panes
5-7
5
Debugging Programs
5.1.3
Watch Panes
You can monitor the values and comments of the specified S, I, O, M, C, D, and G registers on
the Watch 1, 2, and 3 Panes. Realtime monitoring is possible if the Machine Controller is con-
nected. You can edit the values.
Displaying Watch Data
1.
Click one of the tabs for the Watch 1, 2 or 3 Panes.
Select
Monitor
−
Watch
from the Launcher. The Watch 1 Pane will be displayed.
Note: You can show or hide the Watch 1, 2, and 3 Panes by selecting
View
−
Watch
−
Watch 1, View
−
Watch
−
Watch 2
, or
View
−
Watch
−
Watch 3
from the menu bar.
2.
Double-click the
Variable
Column or press F2 to show the text cursor, and then enter
the register or variable register to monitor.
Note: 1. You can also drag or copy registers from the ladder program or from the Variables Pane.
2. When monitoring D registers, enter the program number as shown below.
3.
Press the
Enter
Key.
The contents of the specified register will be displayed.
If you right-click a row, you can select
Decimal, Hex, Binary,
or
ASCII
from the pop-up menu to
change the data type of the
Value
Column.
When a project link is used, the data registered in the Watch Pane is saved only to the Machine
Controller. To apply the watch data to the project file, transfer all of the data from the Machine
Controller.
Note
Содержание MP3000 Series
Страница 153: ...4 1 User Program Types and Execution Timing 4 1 2 Motion Programs 4 20 Ladder Program Example...
Страница 212: ...5 4 Tuning 5 70 5 4 1 Using SigmaWin When Using a Servo 5 70 5 4 2 Using DriveWizard Plus When Using an Inverter 5 70...
Страница 274: ...5 3 Monitoring Machine Operation 5 3 3 Realtime Tracing 5 64...