10 Cable Wiring
10.2Connecting Cables
10-6
176183-1CD
HW1483638
MH5S
(II)
/MH5F
10.2
Connecting Cables
10.2.1 S-Head and Base
• Refer to
Table 10-3 “Checklist for Cable Wiring Parts in S-Head and
and
Fig. 10-3 “Cable Wiring in S-Head and Base”
1. Insert the internal wiring harness mounted the base connector in the
S-head from the back side of the manipulator.
2. Mount the support on the internal wiring harness. Mount the
saddle on the spring part of the internal wiring harness (at the
second or third winding from the top). Then fix it with the GT-SA
bolt .
3. Mount the support on the S-head with the GT-SA bolts .
Tighten
the GT-SA bolts with a tightening torque shown in
4. Connect the connector of the S-axis motor to the internal wiring
harness and remove the backup battery.
5. Push the internal wiring harness in the base and accommodate it. At
this time, be very careful not to pinch the cable between the base and
the connector.
6. After accommodate the internal wiring harness, mount the base
connector on the base with the hexagon socket button head
screws .
7. Insert the internal wiring harness to the L-arm side.
8. Mount the cover with the hexagon socket button head screws .
10.2.2 U-Arm and Casing
• Refer to
Table 10-2 “Checklist for Cable Wiring Parts in Casing and
Fig. 10-2 “Cable Wiring in Casing and L-Arm”
1. Insert the internal wiring harness in the casing.
2. Connect the connectors of the L- and U-axis motors to the internal
wiring harness and remove the backup batteries.
3. Mount the saddles
on the spring part of the internal wiring
harness (at the second or third winding from the top). Fix it with the
hexagon socket head cap screws
and the white-marked part of
the internal wiring harness with the cable tie.
4. Mount the cover on the L-arm with the hexagon socket button head
screws .
5. Mount the support on the internal wiring harness in the casing.
Mount the saddle on the spring part of the internal wiring harness (at
the second or third winding from the top). Fix it with the hexagon
socket head cap screw and the white-marked part of the internal
wiring harness with the cable tie.
6. Connect the connector of the R-axis motor to the internal wiring
harness and remove the backup battery.
7. Insert the internal wiring harness in the wrist unit.
8. Mount the support on the casing with the hexagon socket head cap
screws .
8
5
4
3
5
6
6
8
7
1
2
9
11
10 12
7
8
4
6
5
4
3
86 of 99