2-1
169861-1CD
HW1482771
2
Setup
2.1 Setup Flow
Weldcom Function: Arc
Welding Digital I/F
2
Setup
2.1
Setup Flow
Setup the DX200 with the following procedure.
2.2
DX200 System Software Upgrade
The WELDCOM function is incorporated into the system software version,
DN1.00.00(
)-00 or later. If DX200 has a version of earlier than DN1.00
installed, upgrade the version by following the procedure below. DX200
with DN1.00.00(
)-00 or later does not need to be upgraded.
MOTOWELD-X350 is available for the version DN2.10.00(
)-00 or newer.
FroniusTPSi is available for the version DN1.90.01(
)-78,
DN1.91.00(
)-78, and DN2.15.00(
)-00 or newer. Also, it needs the
MotoPlus function .
2.2.1 Individual Data Backup
Save all the individual data including job and condition files to initialize the
system after the upgrade. Also, save the system configuration file in the
maintenance mode.
2.2.2 System Upgrade
Upgrade the version to DN1.00.00(
)-00 or later. (For detailed
information of the system software upgrade procedure, see “DX200
Upgrade Procedure” 165560-1CD).
DX100 system software upgrade
DX200 system software upgrade
Setting and confirmation of hardware configuration
Connection of welding power source and DX100
Connection of welding power source and DX200
System configuration
17 of 75