5.2 b: Application
YASKAWA EUROPE
SIEP
YASKAWA AC Drive L1000V Technical Manual
106
5
5.2
b: Application
u
b1: Operation Mode Selection
n
b1-02: Up/Down Command Selection
Determines he Up/Down command source in the REMOTE mode. Wire the motor so the elevator goes up when an Up
command is issued.
Setting 0: Operator
Allows the user to enter Up/Down commands from the digital operator. Use this setting when performing a test run only.
Setting 1: Control Circuit Terminal
Up/Down commands are issued from the control circuit terminals. This is the standard setting used in most elevator
applications.
n
b1-03: Stopping Method Selection
Selects how the drive stops the motor when the Up/Down command is removed or when a Stop command is entered.
Setting 0: Ramp to stop
Ramps the motor to stop at the deceleration ramp set in C1-02. The actual time required for deceleration may vary by
load conditions (mechanical loss, inertia).
Setting 1: Coast to stop
The drive will shut off output to the motor and allow it to coast freely to stop when the Up/Down command is removed.
n
b1-08: Up/Down Command Selection while in Programming Mode
As a safety precaution, the drive will not normally respond to an Up/Down command input when the digital operator is
being used to adjust parameters in the Programming Mode (Verify Menu, Setup Mode, Parameter Settings Mode, and
Auto-Tuning Mode). If required by the application, set b1-08 to allow the drive to run while in the Programming Mode.
Setting 0: Disabled
An Up/Down command is not accepted while the digital operator is in the Programming Mode.
Setting 1: Enabled
An Up/Down command is accepted in any digital operator mode.
Setting 2: Prohibit programming during run
It is not possible to enter the Programming Mode as long as the drive output is active. The Programming Mode cannot be
displayed during Run.
No.
Parameter Name
Setting Range
Default
b1-02
Up/Down Command Selection
0 to 1
1
No.
Parameter Name
Setting Range
Default
b1-03
Stopping Method Selection
0 or 1
0
No.
Parameter Name
Setting Range
Default
b1-08
Up/Down command Selection while in Programming Mode
0 to 2
1
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...