268
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
◆
S4: Rescue Operation
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
S4-01
(06A6)
Light Load Direction
Search Selection
Enables and disables the Light Load Direction Search.
0 : Disabled
1 : Advanced
0
(0, 1)
S4-05
(06AA)
Rescue Operation
Torque Limit
Sets a time limit for Light Load Direction Search.
100%
(0% - 300%)
S4-20
(06B1)
Light Load Search
Override
Defines the source that determines the light load search direction.
0 : Controller Direction
1 : Inverter Direction
0
(0 - 1)
◆
S6: Error Detection
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
S6-01
(06B3)
Motor Contactor
Response Error (SE1)
Detection/Reset
Selection
Determines when the drive should detect a motor contactor response error (SE1). SE1 is
triggered if there is no response from the motor contactor within the time set in S6-10
after the contactor control output has been set.
0 : Detect during stop, SE1 must be manually reset
1 : Detect during stop, SE1 can be automatically reset
2 : No SE1 detection
0
(0 - 2)
S6-02
(06B4)
Starting Current Error
(SE2) Detection Delay
Time
Sets a delay time for starting current error (SE2). SE2 is detected when the drive output
current is below 25% after the Up/Down command has been entered and the brake
release time and the time set to S6-02 have both passed. The brake control command
will not be issued (brake stays applied).
200 ms
(0.00 - [S1-04 - S1-06]
ms)
S6-04
(06B6)
Output Current Error
(SE3) Detection Delay
Time
Sets a delay time for detecting an output current fault (SE3). SE3 is detected when the
drive output current drops below 25% after the brake has released.
200 ms
(0 - 5000 ms)
S6-05
(06B7)
Brake Response Error
(SE4) Detection Time
Sets a delay time for detecting a brake response error (SE4). SE4 is detected when an
output terminal set for
“
Brake release
”
(H2-xx = 50) and an input terminal set for
“
Brake
feedback
”
(H1-xx = 79) do match for the time set to S6- 05.
500 ms
(0 - 10000 ms)
S6-15
(06BB)
Speed Reference Loss
Detection
Enables speed reference loss detection when D1-18 = 1 and H1-xx ≠ 53.
0 : Disabled
1 : Enabled
0
(0, 1)
S6-16
(06BC)
Restart after Baseblock
Selection
Allows the drive to restart the motor after returning to normal operation from Baseblock
state (H1-xx = 8/9) or from Safe Torque-Off state (Safe Disable inputs H1 and H2
enabled) while the Up/Down command is still active.
0
(0, 1)
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
Содержание LA500
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 24: ...1 2 Features and Advantages of Control Methods 24 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 38: ...2 8 Install the Keypad in a Control Panel or Another Device 38 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 134: ...5 5 EN81 20 Compliant Circuit with no Motor Contactor 134 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 135: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 135 6 Network Communications 6 1 MEMOBUS Modbus Communications 136...
Страница 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...