Connection Diagramm

Fig 4  Wiring Diagram

Voltage adjust-
ment

DC reactor to improve input

power factor (optional)

Braking Resistor
unit (optional)

Link

Magnetic

Contactor

3-phase power
380 to 480V
50/60Hz

L1

L2

L3

PE

Line

Filter

L1(R)

L2(S)

L3(T)

(+1)

(+2)

(-)

B1

B2

U/T1

V/T2

W/T3

TA1

PG-X2

(Optional)

Motor

IM/PM

TA3

TA2

P

P

PG

S1

S3

S2

S4

S5

S6

S7

BB

BB1

Multi function 
Inputs
(Factory setting)

Forward run/stop

Reverse run/stop

Nominal Speed

Inspection Run

Intermediate Speed

Leveling Speed

Not used

Hardware Baseblock 
(note 3)

SC

+24V, 8mA

IP24V (24V)

CN5(NPN setting)

A Pulse

B Pulse

Z Pulse

Pulse Monitor Output
RS-422 
(100m or less)

E(G)

MA

MB

MC

Fault contact output
250VAC, max. 1A 
30VDC, max. 1A

M1

M2

M3

M5

M4

M6

Brake Command
(Factory setting)

Contactor Control
(Factory setting)

Inverter Ready
(Factory setting)

Multi-function
contact output
250VAC, max. 1A 
30VDC, max. 1A

Analog input power
15V, 20mA

Master speed
reference 0 to 10V

+V

A1

AC

0 V

P

2CN

2kOhm

Analog input

(Speed reference)

2kOhm

0 to 10 V

Input option cards

Optional control power 

supply input for Rescue 

Operation

to terminal B1

to terminal -

Control Power

Supply Input

P0

N0

Twisted-pair
wires

Shielded
wires

Note:
1.  Main circuit terminals are indicatied with double circles and

 control circuit terminals are indicatied with a single circles

2.  The CN5 factory setting is NPN
3.  To enable the inverter both inputs, BB and BB1 must be closed. If 

only one of the inputs is closed, “BB” will be displayed in the 
operator panel and the inverter will not start.

Output option 

cards

3CN

Varispeed L7

Содержание L7B

Страница 1: ...19 Autotuning 20 Autotuning Mode Selection 20 Autotuning Alarms and Faults 21 Autotuning Procedure with Induction Motors 22 Autotuning Procedure for PM Motors 23 PM Motor Encoder Offset Tuning 24 Rid...

Страница 2: ...reparation of this manual Nevertheless Yaskawa assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained in thi...

Страница 3: ...esult in electric shock Wire the Inverter so that the Run command switches off when a Stop command or Fast stop command is input to termi nal BB or terminal BB1 If the Run command is not removed then...

Страница 4: ...ith any option cards other than the PG F2 card and not using the braking sequence recommended by this Inverter set the following braking sequences externally After inputting the operational order or c...

Страница 5: ...tion Doing so will cause damage to the Inverter or the interior parts Cables must not be connected or disconnected nor signal tests carried out while the power is switched on The Varispeed L7 DC bus c...

Страница 6: ...sons with any form of access to the inverters Intended Use Frequency inverters are intended for installation in electrical systems or machinery Their installation in machinery and systems must conform...

Страница 7: ...on can damage the inverter and motor If a motor is exchanged or operated the first time always set up the motor control relevant parameters using the nameplate data or perform autotuning Do not change...

Страница 8: ...s Laying Cables Measures Against Line Borne Interference Line filter and frequency inverter must be mounted on the same metal plate Mount the two components as close to each other as possible with cab...

Страница 9: ...owder oil water or other foreign matter does not get into the Inverter Do not install the Inverter on combustible material such as wood Install the Inverter in a location free from radioactive materia...

Страница 10: ...less in a panel Always provide enough space for suspension eye bolts and the main circuit lines when installing an Inverter with an output of 22 kW or more in a panel A 50 mm min 30 mm min 30 mm min B...

Страница 11: ...e 3 7 140 280 177 126 266 7 59 5 4 140 280 177 126 280 266 7 0 59 5 4 140 280 177 126 280 266 7 0 59 5 4 M5 Fan 5 5 7 5 200 300 197 186 285 8 65 5 2 3 6 200 300 197 186 300 285 8 65 5 2 3 6 200 300 19...

Страница 12: ...e following precautions should be considered for the ground connection Do not share the ground wire with other devices such as welding machines or power tools Always use a ground wire that complies wi...

Страница 13: ...when OFF S3 Nominal speed Nominal speed when ON Functions are selected by setting H1 01 to H1 05 S4 Inspection Run Inspection RUN when ON S5 Intermediate speed Intermediate speed when ON S6 Leveling...

Страница 14: ...wn for the connection of contacts or NPN transistors 0V common and sinking mode This is the default setting For the connection of PNP transistors or for using a 24V external power supply refer to Tabl...

Страница 15: ...on To protect the motor from overheating set the E2 01 parameter in the Inverter to the same value as the level of the motor rated current For Meeting CE Marking For precautions on the CE Marking refe...

Страница 16: ...30VDC max 1A M1 M2 M3 M5 M4 M6 Brake Command Factory setting Contactor Control Factory setting Inverter Ready Factory setting Multi function contact output 250VAC max 1A 30VDC max 1A Analog input powe...

Страница 17: ...parameter numbers and decrements set values Used to move to the previous item or data DATA ENTER Key Enters menus and parameters and set validates parameter changes RUN Key Starts the Inverter operati...

Страница 18: ...rce Analog Input Digital operator b1 02 0 Set up the analog digital I O s in the H1 xx H2 xx and H3 xx parameters Set up the Acceleration Deceleration times C1 xx S Curves Jerk C2 x Make test runs Fin...

Страница 19: ...ode Selection As the first thing after power up one of the four control modes must be selected depending on the machine type The Closed Loop Vector modes require PG feedback cards Table 4 shows the re...

Страница 20: ...p value E2 02 and the no load current E2 03 after the first run with nominal speed Autotuning for Line to Line Resistance T1 01 2 Non rotating autotuning for line to line resistance can be used in V f...

Страница 21: ...tor contactors have to be closed 5 For autotuning the BB and BB1 signals must be ON Inverter must not be in base block condition 6 Confirm that the motor is mechanically fixed and can not move 7 Power...

Страница 22: ...02 2 3 Yes Enter auto tuning mode and set parameter T1 01 2 Set T1 02 Motor rated power T1 04 Motor rated current Press the UP button until Tuning Ready display appears Set T1 02 Motor rated power T1...

Страница 23: ...wer supply if it is OFF Check parameter n8 35 If EnDat Hiperface is used check the encoder power supply check the CLOCK and DATA signal wiring Switch off the power supply No Yes Does a OPE06 fault occ...

Страница 24: ...nd eliminate the fault source Open the contactors open the base block inputs and close the brake FINISH Is it possible to remove the ropes Does a CPF24 fault occur Balance the car so that it does not...

Страница 25: ...Source Selection The speed reference source can be selected using parameter b1 01 The factory setting is the digital operator b1 01 0 i e the speeds can be selected using digital inputs Speed Selecti...

Страница 26: ...ut the inverter decelerates to the leveling speed d1 17 when the selected speed signal is removed Inspection Speed can not be selected as travel speed To select the leveling speed as travel speed the...

Страница 27: ...f d1 18 is set to 2 and no digital input is set to nominal speed selection the speed reference with speed selection input set is nominal speed d1 09 When the leveling speed signal is set the inverter...

Страница 28: ...eleration time n5 05 must be tuned Motor Acceleration Time Auto Tuning n5 05 Before the n5 02 auto tuning is performed the motor data autotuning and the general setup should have been finished Do the...

Страница 29: ...Increase the gain to improve the responsiveness to the speed reference Decrease the gain if vibrations or oscillations occur IMPORTANT 1 The order of giving the UP or DOWN command has no influence 2 n...

Страница 30: ...04 0 1 or 2 and A1 02 3 or 6 The speed deviation is higher than the F1 10 value for the time F1 11 or longer Reduce the load Lengthen the acceleration time and deceleration time Check the mechanical s...

Страница 31: ...rent exceeded the motor over load curve The overload curve is adjustable using parameter E2 01 Motor Rated Current L1 01 Motor Protection Selection and L2 02 Motor Protection Time Con stant Recheck th...

Страница 32: ...eck the input voltage and the wiring of the input terminals Extend the settings in C1 01 03 05 07 Main Circuit MC Operation Failure No MC response during Inverter operation Replace the Inverter UV2 CT...

Страница 33: ...too high or too low Closed Loop Vector for PM only Check the motor wiring Check the motor rated current input value Reduce or increase the current level for leakage inductance tuning by changing para...

Страница 34: ...he proportional gain 2 and the inte gral time 2 of the speed control loop ASR for the minimum frequency The setting is active only for acceleration C5 04 ASR integral I time 2 C5 06 ASR delay time Set...

Страница 35: ...ed 1 Enabled Param Num Name Description n5 03 Feed forward proportional gain Speed reference response will increase as the setting of n5 03 is increased n5 05 Motor accelera tion time tuning 0 Disable...

Страница 36: ...Fault 1 Major Fault U2 12 Output terminal status at fault U2 13 Operation status at fault U2 14 Cumulative operation time at fault Fault History Data U3 01 to U3 04 Last fault to Fourth last fault U3...

Отзывы: