24
YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
Bit 0 - 7 : The LSB of the actual 15-bit Braking Distance
Data Byte 2
Bit 8 - 14 : The MSB of the actual 15-bit Braking Distance
Data Byte 1
Bit 15 : Mode Identification
The braking distance will only be available if the mode identification is cleared.
16-bit braking distance
The two data bytes are containing the actual 16-bit braking distance. The maximum braking distance is limited to
FFFF (Hex) (65535 mm).
While the lift car is stationary or just starting, the value for the braking distance is clamped at FFFF (Hex). During
acceleration, the value increases from 0. During constant speed, the braking distance remains constant.
Bit 0 - 7 : The LSB of the actual 16-bit Braking Distance
Data Byte 2
Bit 8 - 15 : The MSB of the actual 16-bit Braking Distance
Data Byte 1
Transmitted Information Using Data Information Types
Transmitted Information using Data Information Type ’0’
The two data bytes are alternately filled by the braking distance (indicated to the lift controller by bit 15 being '0')
and the Extended Status information (bit 15 being '1'). These values must be handled carefully because each type
of transmitted information is updated every 30 ms only. For DCP3, the braking distance always reads 0.
Data Byte 1
Data Byte 2
Bit 15
Bit 8 - 14
Bit 0 - 7
0
15-bit braking distance
1
Extended status
Transmitted Information using Data Information Type ’1’
This mode is not used in DCP3. In this mode, the two data bytes will be used only to transmit the actual 15-bit
braking distance.
Data Byte 1
Data Byte 2
Bit 15
Bit 8 - 14
Bit 0 - 7
0
15-bit braking distance MSB
15-bit braking distance LSB
If bit 15 = 0, the value is evaluated as 15-bit braking distance.
Transmitted Information using Data Information Type ’2’
In this mode, the two data bytes are used only for transmission of the Extended Status of the drive controller.
Data Byte 1
Data Byte 2
Bit 15
Bit 8 - 14
Bit 0 - 7
1
Extended status
If data shall be evaluated as Extended Status, bit 15 must be set to
’
1
’
.
Transmitted Information using Data Information Type ’3’
This mode is not used in DCP3. In this mode, the data bytes are exclusively used to transmit the actual 16-bit
braking distance.
Data Byte 1
Data Byte 2
Bit 8 - 15
Bit 0 - 7
16-bit braking distance MSB
16-bit braking distance LSB
Transmitted Information using Data Information Type ’4’
In this mode, the data bytes are exclusively used to transmit the Extended Status of the drive controller.
Data Byte 1
Data Byte 2
Bit 15
Bit 8 - 14
Bit 0 - 7
1
Extended status
Содержание L1000A CIMR-LC F Series
Страница 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 97: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 97 15 Appendix EN...
Страница 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Страница 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Страница 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...