Figure 6.2 Typical DCP Topology
Drive and lift controller are linked via RS-485 using the fixed communication settings:
•
Baud rate: 38,400 Baud
•
Parity: none
•
Data bits: 8
•
Stop bits: 1
■
Messages
•
Time-critical, high speed process data (e.g. remaining distance, switch-off points, travel commands, etc)
•
Non time-critical communication data (e.g. display control, transfer of keypad codes, etc.)
•
Not more than 2 bytes of communication data are transferred with each message; the remaining bytes being
used for fast process data.
•
Each message is provided with a checksum byte
Master Messages from Lift Controller to Drive Controller
Fixed length of 6 bytes
Process Data
Communication Data
Checksum
1
2
3
4
5
6
Command Byte
Data Byte 1
Data Byte 2
Communication Byte 1
Communication Byte 2
Checksum
Slave Messages from Drive Controller to Lift Controller
Fixed length of 6 bytes
Process Data
Communication Data
Checksum
1
2
3
4
5
6
Status Byte
Data Byte 1
Data Byte 2
Communication Byte 1
Communication Byte 2
Checksum
◆
DCP Master Messages from Lift Controller to Drive Controller
■
Command Byte
Process Data
Communication Data
Checksum
1
2
3
4
5
6
Command Byte
Data Byte 1
Data Byte 2
Communication Byte 1
Communication Byte 2
Checksum
The first byte of the message is called command byte. It contains the following information:
Bit B0 : Drive controller enable
DCP3 and DCP4:
Information for the drive that there will be activation soon. This bit is set during a travel.
0 : No activation of the drive (e.g. finish of travel or travel interruption)
1 : Drive activation during travel
Bit B1 : Travel command (DCP3); Change of actual distance (DCP4)
DCP3:
The speed is set with the travel command.
This bit is cleared at the deceleration point and the drive slows down to V0 (Crawl speed).
DCP4:
Remaining Distance Travel: With a travel dependent on distance, bit B1 is cleared since the drive controller itself
determines the optimum switch-off point. The speed transferred before the start of the travel is just a limit.
Содержание L1000A CIMR-LC F Series
Страница 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 97: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 97 15 Appendix EN...
Страница 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Страница 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Страница 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Страница 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...