3.1 Basic Functionality
Programs
3-13
3
CPU Unit Functionality
*1. System Work Number Setting
• When the Motion Program Is Registered in M-EXECUTOR:
The system work number cannot be specified. The system will use the definition number as the system work num-
ber.
• When a Motion Program Is Called from a Ladder Program with an MSEE Instruction:
OFF: The system will use an automatically acquired system work number. The system work number will be different each
time.
ON: The work number that is specified by the system will be used.
However, if the work number is assigned to the M-EXECUTOR, a No System Work Available Error (Status Flag
Bit E) is reported.
*2. Interpolation Override Setting
OFF: The interpolation override is always 100%.
ON: The interpolation override in the parameter setting is used.
Note: 1. Use the specified signal types for the ladder program inputs.
2. At startup, the motion programs for which the Request for Start of Program Operation control signals are ON
will be executed.
Bit D
System Work
Number Setting
*1
To specify a system work number, set this bit to 1.
0: Do not specify a system work number.
1: Specify a system work number.
Bit E
Interpolation
Override Setting
*2
To specify an interpolation override, set this bit to 1.
0: Do not specify an interpolation override.
1: Specify an interpolation override.
Bit F
Reserved for sys-
tem.
−
Continued from previous page.
Bit No.
Name
Description