3.3 Switch Specifications
3.3.2 Rotary Switches (Address Setting)
3-5
3
G
W3100
S
pecification
s
3.3.2
Rotary Switches (Address Setting)
Use these switches to set the GW3100 station address (03 to EF hex) as a MECHATROLINK-III
slave.
The numbers that you set are converted to a hexadecimal number between 03 and EF. Set the
arrows toward the desired numbers, setting the upper digit on the top rotary switch (x16
1
) and
the lower digit on the bottom rotary switch (x16
0
).
3.3.3
SAVE Switch (Saving to Flash Memory)
This switch is used to save the parameter settings to flash memory.
Name
Status
Operation
Default
Remarks
X16
1
0 to F
Upper digit of station
address
0
“F” cannot be used.
X16
0
0 to F
Lower digit of station
address
3
Setting Address C8 (hex)
Top rotary switch (x16
1
): Set to C.
Bottom rotary switch (x16
0
): Set to 8.
×16
1
×16
0
01
2
3
456
78
9A
BCDEF
01
2
3
456
78
9A
BCDEF
Example
Name
Status
Operation
Default
Remarks
SAVE
ON
Saving to flash memory
OFF
If you keep the SAVE switch ON for
three seconds, the current parameter
settings will be saved to non-volatile
memory.
When you save the settings to flash
memory, the RUN indicator will flash.
OFF
Normal operation
SAVE