8.6 Parameter Details
8.6.4 Alarm Details
8-26
8.6.4
Alarm Details
The alarm bit details are as follows:
8.6.5
Details in Extended Address n Communications Status
(n = 0 to 3)
The bit details in the extended address n communications status are as follows:
Bit
Name
Meaning
0
Param
0: Normal
1: Parameter setting error
1
M-III Cycle
0: Normal
1: M-III transmission cycle setting error
2
M-III Address
0: Normal
1: M-III station address setting error
3
WDT
0: Normal
1: Watchdog timeout error
4
Flash
0: Normal
1: Saving to flash memory failed.
5 to 1F
Reserved
Reserved for system.
Bit
Name
Meaning
0
D_ALM
0: Normal
1: Device alarm
1
D_WAR
0: Normal
1: Device warning
2
CMDRDY
0: Commands cannot be received.
1: Ready to receive commands.
3
ALM_CLR_CMP
0: ALM_CLR execution not completed.
1: ALM_CLR execution completed.
4 to 7
Reserved
Reserved for system.
8 to B
CMD_ALM
0: Normal
1 to 7: Not used.
8: Unsupported command received.
9: Data out of range
A: Command execution condition error
B: Subcommand combination error
C: Phase error
D to F: Not used.
C to F
COMM_ALM
0: Normal
1: Isolated FCS error
2: Reference data not received, isolated error.
3: Sync frame not received, isolated error.
4 to 7: Not used.
8: Two consecutive FCS errors
9: Reference data not received two times consecutively.
3: Sync frame not received two times consecutively.
B to F: Not used.