Auto-Tuning automatically sets this parameter to the value input for [Motor Rated Power].
◆
E5: PM Motor Settings
E5 parameters
set PM motor data.
Set
E5-01
to the motor code when you use a PM motor recommended by Yaskawa and the drive will automatically set
E5
and other related motor parameters to the optimal values.
Do Auto-Tuning for all other PM motors. If information from motor nameplates or test reports is available, you can
enter the
E5 parameters
manually.
Note:
•
The keypad shows
E5-xx
only when
A1-02 = 5 [Control Method Selection = OLV/PM]
.
•
If you use
A1-03 [Initialize Parameters]
to initialize the drive, it will not reset
E5-xx parameters
.
■
E5-01: PM Motor Code Selection
No.
(Hex.)
Name
Description
Default
(Range)
E5-01
(0329)
PM Motor Code Selection
Sets the motor code for Yaskawa PM motors. The drive uses the motor code to automatically set
some parameters to their correct settings.
FFFF
(0000 - FFFF)
Note:
If the drive hunts or shows an alarm after you enter a motor code, use the keypad to enter the value shown on the nameplate to
E5-xx
.
■
E5-02: PM Motor Rated Power
No.
(Hex.)
Name
Description
Default
(Range)
E5-02
(032A)
PM Motor Rated Power
Sets the PM motor rated output in the units set in
o1-58 [Motor Power Unit Selection]
.
Determined by o2-04
(0.13 - 650.00 HP)
The drive will automatically set this parameter the next time you do Auto-Tuning.
•
PM Motor Parameter Settings
•
PM Stationary Auto-Tuning
•
PM Rotational Auto-Tuning
■
E5-03: PM Motor Rated Current (FLA)
No.
(Hex.)
Name
Description
Default
(Range)
E5-03
(032B)
PM Motor Rated Current
(FLA)
Sets the PM motor rated current (FLA).
Determined by o2-04
(10% to 200% of the drive
rated current)
Note:
When the drive model changes, the display units for this parameter also change.
•
0.01 A: 2011 to 2046, 4005 to 4014
•
0.1 A: 2059 to 2273, 4021 to 4302
The drive automatically sets
E5-03
to the value input for
“
PM Motor Rated Current
”
after you do these types of Auto-
Tuning:
•
PM Motor Parameter Settings
•
PM Stationary Auto-Tuning
•
PM StaTun for Stator Resistance
•
PM Rotational Auto-Tuning
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 16: ...i 3 Warranty Information 16 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 158: ...1 22 Defaults by o2 04 Drive Model kVA Selection 158 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...
Страница 506: ...2 14 Y Application Features 506 YASKAWA TOEPYAIHV6002A HV600 Drive Programming...