YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
311
■
H5-22: Speed Search from MODBUS
No.
(Hex.)
Name
Description
Default
(Range)
H5-22
(11CF)
Speed Search from
MODBUS
Enables the MEMOBUS/Modbus communication register Speed Search function (bit0 of 15DFH).
0
(0, 1)
0 : Disabled
1 : Enabled
If you set
H5-22 = 1
and
H1-xx = 62 [Speed Search from Fref]
at the same time, the drive will detect
oPE03 [Multi-
Function Input Setting Err]
.
■
H5-23: BACnet Max Master
No.
(Hex.)
Name
Description
Default
(Range)
H5-23
(158D)
BACnet Max Master
Sets the maximum number of master MAC ID to scan to when the drive polls for the next node (Poll
for Master).
7F
(1 - 7F)
■
H5-24: BACnet Max Info Frames
No.
(Hex.)
Name
Description
Default
(Range)
H5-24
(3DA0)
BACnet Max Info Frames
Sets the maximum number of information frames for BACnet.
3
(1 - 255)
■
H5-25: Function 5A Register 1 Selection
No.
(Hex.)
Name
Description
Default
(Range)
H5-25
(1589)
RUN
Function 5A Register 1
Selection
Returns the contents of the specified MEMOBUS/Modbus communications register when responding
to the master device.
0044H (U1-05)
(0000H - FFFFH)
■
H5-26: Function 5A Register 2 Selection
No.
(Hex.)
Name
Description
Default
(Range)
H5-26
(158A)
RUN
Function 5A Register 2
Selection
Returns the contents of the specified MEMOBUS/Modbus communications register when responding
to the master device.
0045H (U1-06)
(0000H - FFFFH)
■
H5-27: Function 5A Register 3 Selection
No.
(Hex.)
Name
Description
Default
(Range)
H5-27
(158B)
RUN
Function 5A Register 3
Selection
Returns the contents of the specified MEMOBUS/Modbus communications register when responding
to the master device.
0042H (U1-03)
(0000H - FFFFH)
■
H5-28: Function 5A Register 4 Selection
No.
(Hex.)
Name
Description
Default
(Range)
H5-28
(158C)
RUN
Function 5A Register 4
Selection
Returns the contents of the specified MEMOBUS/Modbus communications register when responding
to the master device.
0049H (U1-10)
(0000H - FFFFH)
Содержание H6B1A002
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...