962
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
Note:
•
If response to the speed reference is slow, increase the value set in
n5-03
.
•
Increase the value set in
n5-03
when response to the speed reference is slow.
–
The speed is overshooting.
–
A negative torque reference is output when acceleration ends.
■
n5-04: Speed Response Frequency
No.
(Hex.)
Name
Description
Default
(Range)
n5-04
(05B3)
RUN
Expert
Speed Response Frequency
Sets the response frequency for the speed reference. Usually it is not necessary to change this
parameter.
Determined by A1-02
(0.00 - 500.00 Hz)
If you set
n5-03 [Feed Forward Control Gain]
too high, the motor speed will momentarily increase to more than the
set frequency.
◆
n6: Online Tuning
n6 parameters
are used to set the online tuning function for motor line-to-line resistance.
The Online Tuning for motor line-to-line resistance is used to prevent degradation of speed control accuracy due to
motor temperature fluctuation and motor stalls due to insufficient torque.
■
n6-01: Online Tuning Selection
No.
(Hex.)
Name
Description
Default
(Range)
n6-01
(0570)
Online Tuning Selection
Sets the type of motor data that Online Tuning uses for OLV control.
0
(0 - 2)
0 : Disabled
1 : Line-to-Line Resistance Tuning
The drive adjusts the motor line-to-line resistance during run. This procedure is applicable for speed values 6 Hz and
less. It also adjusts the motor resistance value to increase the overload capacity in the low speed range.
2 : Voltage Correction Tuning
The drive adjusts the output voltage during run to increase overload tolerance and minimize the effects of high
temperatures on speed precision.
Note:
Setting 2 is enabled only when
b8-01 = 0 [Energy Saving Control Selection = Disabled]
.
■
n6-05: Online Tuning Gain
No.
(Hex.)
Name
Description
Default
(Range)
n6-05
(05C7)
Expert
Online Tuning Gain
Sets the compensation gain when
n6-01 = 2 [Online Tuning Selection = Voltage Correction Tuning]
.
Usually it is not necessary to change this parameter.
1.0
(0.1 - 50.0)
When you use a motor that has a large secondary circuit time constant, decrease the setting value.
If the drive detects
oL1 [Motor Overload]
, increase the setting value in 0.1-unit increments.
■
n6-11: Online Resistance Tuning
No.
(Hex.)
Name
Description
Default
(Range)
n6-11
(1B56)
Expert
Online Resistance Tuning
Sets the responsiveness for online resistor tuning. Set this parameter to approximately
1.000
to enable
the function. The function is disabled when the value is
0.000
.
0.000
(0.000 - 1.000)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...