YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
917
Does DC injection braking and short circuit braking as specified by
b2-04 [DC Inject Braking Time at Stop]
and
b2-
13 [Short Circuit Brake Time @ Stop]
.
■
L2-31: KEB Start Voltage Offset Level
No.
(Hex.)
Name
Description
Default
(Range)
L2-31
(045D)
Expert
KEB Start Voltage Offset
Level
Sets the KEB start voltage offset.
Determined by A1-02
(200 V Class: 0 - 100 V,400
V Class: 0 - 200 V)
The drive uses this formula to calculate the KEB start voltage:
KEB start voltage =
L2-05 [Undervoltage Detect Level (Uv1)] + L2-31
◆
L3: Stall Prevention
L3 parameters
set the Stall Prevention function and overvoltage suppression function.
■
Stall Prevention
If the load is too heavy or the acceleration and deceleration times are too short, the motor can slip too much because it
cannot work at the same rate as the frequency reference. If the motor stalls during acceleration, current increases as
the slip increases to cause an
oC [Overcurrent]
,
oL2 [Drive Overload]
, or
oL1 [Motor Overload]
and the drive will
stop. If the motor stalls during deceleration, too much regenerative power will flow back into the DC bus capacitors,
and cause the drive to fault out from
ov [Overvoltage]
and the drive will stop.
The stall prevention function will let the motor get to the set speed without stalling and it is not necessary for you to
change the acceleration or deceleration time settings. You can set a separate stall prevention functions for
acceleration, operating at constant speeds, and deceleration.
■
Overvoltage Suppression Function
Decreases the regenerative torque limit and increases the output frequency when the DC bus voltage increases to
prevent
ov
. This function can drive loads with cyclic regenerative operation, for example punch presses or other
applications with repeated crank movements. When you use this function, set
L3-11 = 1 [Overvoltage Suppression
Select = Enabled]
.
The drive adjusts the regenerative torque limit and the output frequency during overvoltage suppression to make sure
that the DC bus voltage is not more than the level set in
L3-17 [DC Bus Regulation Level]
.
Set these parameters as necessary when you use the overvoltage suppression function:
•
L3-20 [DC Bus Voltage Adjustment Gain]
•
L3-21 [OVSuppression Accel/Decel P Gain]
•
L3-24 [Motor Accel Time @ Rated Torque]
•
L3-25 [Load Inertia Ratio]
Note:
•
When overvoltage suppression is triggered, the motor speed is more than the frequency reference. Do not use overvoltage suppression for
applications where the frequency reference and the motor speed must align.
•
When you use a braking resistor, set
L3-11 = 0 [Disabled]
.
•
The overvoltage suppression function is enabled only when you operate immediately below the maximum frequency. Overvoltage
suppression does not increase the output frequency to more than the maximum frequency. Make sure that the motor and machine
specifications are correct for the application, then increase the maximum frequency.
•
If there is a sudden increase to a regenerative load,
ov
can occur.
■
L3-01: Stall Prevention during Accel
No.
(Hex.)
Name
Description
Default
(Range)
L3-01
(048F)
Stall Prevention during
Accel
Sets the method of the Stall Prevention During Acceleration.
1
(0 - 3)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...